Use:

Standard:ASTM D7949-14



Evaluation of the entire cross-section and the entire length of the deep foundation element measuring heat generated by curing cement to assess the quality of drilled shafts/bored piles, augered cast in place (ACIP)/continuous flight auger (CFA) or drilled displacement piles, slurry walls, barrettes, soil nails, and jet grouted columns.
 

  • Meets or Exceeds the requirements of ASTM D7949- Standard Test Methods
  • Evaluates concrete quality inside and outside the reinforcing cage
  • Accelerates construction with tests conducted during concrete curing
  • Reveals necking or inclusions, bulges, variations in concrete cover, shape of shaft and cage alignment
  • Thermal Wire® Cables can replace access tubes

 

The Thermal Integrity Profiler (TIP) uses the heat generated by curing cement to assess the quality of drilled shafts and of bored, augered cast in place, continuous flight auger or drilled displacement piles. It may also be used for quality control and shape evaluation of jet grouting, slurry walls, and diaphragm walls. TIP evaluates the entire cross-section and the entire length of the foundation. Results are available shortly after shaft installation is concluded: TIP reveals necks or inclusions (regions that are colder than average), bulges (regions that are warmer than average), variations in concrete cover, and the shape of the shaft and cage alignment.

The average temperature within a concrete shaft is dependent on its diameter, the concrete mix design and on the time of measurement relative to concrete casting. Measured temperatures at the reinforcement cage vary with the distance to the center of the shaft and with the concrete cover.

The TIP starter system includes the TIP Main Unit and 12 Thermal Acquisition Ports (TAPs), along with the TIP Reporter Software. THERMAL WIRE® cables (smart sensing cables fitted with uniformly spaced digital temperature sensors) are ordered separately depending on the length and quantity needed. The cables are tied to the rebar cage and cast into the shaft.

TIP Software

Data collected by the TIP system is downloaded to a computer for analysis by the TIP Reporter Software. The TIP Reporter Software displays measured temperatures versus depth and mapped on cross sections of the shaft to provide profiling data.  The Thermal Integrity Profile software helps identify areas of concern such as potential over-pour bulges, necking, or cage alignment irregularities. TIP Reporter also estimates the concrete cover along the entire length of the shaft.  In addition to TIP temperature measurements, this analysis requires the total concrete volume as an additional input.  The estimated effective shaft radius, reinforcement cage location and the concrete cover of the reinforcement bars can then be determined.

 

The Thermal Profiling Method was developed at the University of South Florida and originally implemented by Foundation and Geotechnical Engineering LLC (FGE). Research and development are a joint effort of ”FGE” and PDI. The TIP conforms to ASTM Standard ”D7949 – Standard Test Methods for Thermal Integrity Profiling of Concrete Deep Foundations.”

Winner of:

  • ”2012 MAGNET/NASA Manufacturing Innovation Project Award”
  • ”2013 NOVA Award from the Construction Innovation Forum”
  • ”2013 Deep Foundations Institute C. William Bermingham Award for Innovation”
  • ”2015 American Society of Civil Engineers Charles Pankow Award for Innovation”

1Cotton, D., Ference, M., Piscsalko, G., and Rausche, F., (2010) “Pile Sensing Device and Method of Making and Using the Same” US Patent 8,382,369.
2Mullins, A. G. and Kranc, S. C., (2004), “Method for Testing the Integrity of Concrete Shafts,” US Patent 6,783,273.

 

Technical Specification

Main Unit

Physical

  • Size: 272 mm X 212 mm X 60 mm (10.7 in x 8.3 in x 2.4 in)
  • Weight: 2.04 Kg (4.5 lbs.)
  • Sunlight readable VGA color display for any lighting conditions, resolution 640 pixels x 480 pixels
  • Screen size: 21.3 cm (8.4 in)
  • Temperature Range: Operating: -20 o C to 40o C (4 o F to 104 o F); Storage: -30 o C to 65o C (-22 o F to 149 o F)
  • Powered by Internal Battery (10-hour duration)
  • Data Storage: Built in 32 GB drive minimum
  • Data Retrieval: USB port or WiFi
  • Microsoft Windows® 10 Operating System

Thermal Acquisition Port for Wires (TAP)

  • Size: 133 mm X 102 mm X 57 mm (5.2 in x 4 in x 2.2 in)
  • Weight: 766 g (1.7 lbs.)
  • Temperature Range: Operating: -20 ° C to 65 ° C (4 o F to 149 o F); Storage -40 ° C to 85 ° C (-40 o F to 185 o F)
  • Contains 1 installed Li-Ion battery or 0.64 grams ELC
  • Internal Battery (28-day duration)
  • Sampling frequency: user programmable, defaulted to once every 15 minutes
  • Hangs from reinforcement cage; may be bolted to cage for security
  • Water Resistant

Thermal Acquisition Port with cloud access for Wires (TAP-Edge)

  • Size: 114 mm X 65 mm X 41 mm (4.5 in x 2.6in x 1.6 in)
  • Weight: 400 g (0.9 lbs.)
  • Temperature Range: Operating: -20 ° C to 65 ° C (4 o F to 149 o F); Storage -40 ° C to 85 ° C (-40 o F to 185 o F)
  • Contains 2 installed Li-Ion battery (14.8 W Hrs.)
  • Internal Battery (20-day duration)
  • Sampling frequency: user programmable, defaulted to once every 15 minutes
  • Hangs from reinforcement cage; may be bolted to cage for security
  • Water Resistant

Thermal Aggregator for Wires (TAG)

  • Size: 160 mm X 80 mm X 57 mm (6.3 in x 3.2 in x 2.2 in)
  • Weight: 540 g (1.2 lbs.)
  • Temperature Range: Operating: -20 ° C to 65 ° C (4 o F to 149 o F); Storage -40 ° C to 85 ° C (-40 o F to 185 o F)
  • Contains 2 installed Li-Ion battery (22.2 W Hrs.)
  • Internal Battery (10-day duration)
  • Sampling frequency: user programmable, defaulted to once every 15 minutes
  • Hangs from reinforcement cage; may be bolted to cage for security
  • Water Resistant

Thermal Wire Tester Box for Wires

  • Size: 133 mm X 102 mm X 57 mm (5.2 in x 4 in x 2.2 in)
  • Weight: 766 g (1.7 lbs.)
  • Temperature Range: Operating: -20 ° C to 65 ° C (4 o F to 149 o F); Storage -40 ° C to 85 ° C (-40 o F to 185 o F)
  • Contains 1 installed Li-Ion battery or 0.64 grams ELC
  • Internal Battery (28-day duration)
  • LCD Display Screen
  • Adapter cable included for splice cables; ADAPTOR CABLE REQUIRED FOR SPLICE CABLES
  • DOES NOT STORE DATA

Thermal Wire® cables

  • Sensor type: digital
  • Furnished in rolls of length starting at 6 m (20 ft) with length increments of 1.5 m (5 ft).
  • Sensor spacing: 305 mm (12 in)
  • Sensor operating temperature: up to 105°C
  • Sensor Accuracy: ± 0.5oC (± 0.9°F)
  • Splicing: multi segment cables available upon request – featuring quick-connect

Thermal Acquisition Port for Probes (TAPP)

  • Size: 114 mm x 133 mm x 57 mm (4.5 in x 5.2 in x 2.2 in)
  • Weight: 822 g (1.8 lbs)
  • Temperature Range: Operating: -20 ° C to 65 ° C (4 o F to 149 o F); Storage -40 ° C to 85 ° C (-40 o F to 185 o F)
  • Internal Battery (8-hour duration)
  • Contains 2 installed Li-Ion batteries (1.28 grams ELC)
  • Sampling frequency: once per second, or as a function of depth (user input)
  • Water Resistant

Probe

  • Sensor type: infrared (four orthogonal sensors)
  • Size: 130 mm x 30 mm (5.1 in x 1.2 in)
  • Weight (Probe): 5.2 kg (11.5 lbs.)
  • Cable length: 60 m or 100 m (200 ft or 332 ft)
  • Weight (60 m Cable): 3.3 kg (7.4 lbs.)
  • Weight (100 m Cable): 8 kg (17.6 lbs.)
  • Sensor operating temperature: up to 105 ° C (221 o F)
  • Removable sensor head
  • Water resistant

Depth Measurement Unit

  • Type: Rotary Encoder
  • Resolution: 2.5 mm (0.1 in)

Other

  • Soft carrying case
  • Full one-year warranty
  • Operates in English or Metric units
  • Technical manual provided in PDF form on a USB drive